PERBANDINGAN DURASI SENTRIFUGASI SAMPEL DARAH TERHADAP HASIL PEMERIKSAAN SKRINING ANTIBODI DI RSUPN DR. CIPTO MANGUNKUSUMO JAKARTA
ABSTRAK
Latar Belakang:Skrining antibodi adalah pemeriksaan untuk mendeteksi adanya antibodi irreguler terhadap sel darah merah didalam plasma. Skrining antibodi merupakan uji pratransfusi yang meliputi pemeriksaan golongan darah ABO dan Rhesus (D phenotype), antibodi skrining dan crossmatching.
Tujuan :Penelitian ini bertujuan untuk mengetahui perbandingan durasi sentrifugasi sampel darah terhadap hasil pemeriksaan skrining antibodi di RSUPN. Dr.Cipto Mangunkusumo Jakarta.
Metode :Jenis penelitian ini adalah adalah penelitian deskriptif kualitatif menggunakan metode analitik-komparatif dengan pendekatan Cross Sectional, jumlah sampel yang diteliti sebanyak 59 sampel darah pasien. Penelitian ini dilakukan di RSCM menggunakan data primer tahun 2020. Sampel untuk penelitian ini menggunakan rumus slovin dan teknik sampling acak sederhana (simple random sampling). Data dianalisis menggunakan uji non-parametrik Mann-Whitney Test untuk mengetahui perbandingaan durasi sentrifugasi 5 menit dan 10 menit.
Hasil :Hasil uji Mann-Whitney Testdiperoleh p=0,115 > 0,05 sehingga dapat disimpulkan tidak terdapat perbedaan hasil skrining antibodi pada sampel darah dengan durasi sentrifugasi 5 menit dan durasi sentrifugasi 10 menit.
Kesimpulan : Dari hasil penelitian dapat disimpulkan bahwa perbandingan durasi sentrifugasi 5 menit dan durasi sentrifugasi 10 menit per 3000 rpm hasil pvalue 0,115 > 0,05 ini berarti tidak terdapat perbedaan yang signifikan pada pemeriksaan durasi sentrifugasi terhadap hasil pemeriksaan skrining antibodi.
Kata kunci : sentrifugasi, skrining antibodi.
ABSTRACT
Back ground :Antibody screening is a test to detect the presence of irregular antibodies against red blood cells in plasma. Antibody screening is a pre-transfusion test which includes examination of ABO and Rhesus (D phenotype) blood groups, antibody screening and crossmatching.
Purpose: The study aims to determine the comparison of the duration of the blood sample centrifugation to the results of antibody screening at DR.Cipto Mangunkusumo Hospital Jakarta.
Method: This type of research is a qualitative descriptive study using a comparative-analytic method with a cross sectional approach, the number of samples studied was 59 patient blood samples. This research was conducted at RSCM using primary data for 2020. The sample for this study used the Slovin formula and simple random sampling techniques. Data were analyzed using the non-parametric Mann-Whitney Test to determine the comparison of the duration of 5 minutes and 10 minutes of centrifugation.
Result:The results of the Mann-Whitney Test obtained p = 0.115> 0.05, so it can be concluded that there is no difference in the results of antibody screening in blood samples with a centrifugation duration of 5 minutes and a centrifugation duration of 10 minutes.
Conclusion:It can be concluded that the comparison between the duration of the centrifugation of 5 minutes and the duration of the centrifugation of 10 minutes per 3000 rpm, the p value is 0.115> 0.05, this means that there is no significant difference in the examination of the duration of centrifugation on the results of the screening examination. antibody.
Key words: centrifugation, antibody screening.
Detail Information
Citation
Ismala Adam. (2020).
PERBANDINGAN DURASI SENTRIFUGASI SAMPEL DARAH TERHADAP HASIL PEMERIKSAAN SKRINING ANTIBODI DI RSUPN DR. CIPTO MANGUNKUSUMO JAKARTA().:
Ismala Adam.
PERBANDINGAN DURASI SENTRIFUGASI SAMPEL DARAH TERHADAP HASIL PEMERIKSAAN SKRINING ANTIBODI DI RSUPN DR. CIPTO MANGUNKUSUMO JAKARTA().:,2020.Text
Ismala Adam.
PERBANDINGAN DURASI SENTRIFUGASI SAMPEL DARAH TERHADAP HASIL PEMERIKSAAN SKRINING ANTIBODI DI RSUPN DR. CIPTO MANGUNKUSUMO JAKARTA().:,2020.Text
Ismala Adam.
PERBANDINGAN DURASI SENTRIFUGASI SAMPEL DARAH TERHADAP HASIL PEMERIKSAAN SKRINING ANTIBODI DI RSUPN DR. CIPTO MANGUNKUSUMO JAKARTA().:,2020.Text